| Input Voltage Class |
220V 3Phase |
| Model |
TDS-V8-L |
| 0P7 |
1P5 |
2P2 |
3P7 |
5P5 |
7P5 |
11 |
15 |
18 |
22 |
30 |
37 |
45 |
55 |
75 |
| Max. Applicable Motor |
HP |
1 |
2 |
3 |
5 |
7.5 |
10 |
15 |
20 |
25 |
30 |
40 |
50 |
60 |
75 |
100 |
| Motor Output(CT)* |
kW |
| 0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
75 |
| Weight (kg) |
2 |
2 |
2.4 |
2.4 |
5.5 |
5.5 |
13.1 |
13.1 |
24.5 |
24.5 |
24.5 |
46 |
46 |
|
|
| Power Output |
Rated Output Capacity(kVA) |
2 |
3 |
4 |
7.5 |
10.1 |
13.7 |
20.6 |
27.4 |
34 |
41 |
54 |
68 |
78 |
|
|
| Rated Output Current(A) |
4.8 |
7.1 |
9.6 |
17.5 |
24 |
32 |
48 |
64 |
80 |
96 |
130 |
160 |
183 |
|
|
| Max. Output Voltage |
3 phase 200~230V |
| Max. Output Frequency(Hz) |
Through parameter setting ( 0 Hz to 400Hz) |
| Power Source |
Rated Voltage, Frequency |
3 Phase 200V~230V,50/60Hz |
| Allowable Voltage Fluctuation |
-15% ~ +10% |
| Allowable Frequency Fluctuation |
±5% |
| |
| Control Characteristics |
Operation Mode |
LED Operator or LCD Operator |
| Control Mode |
Sine PWM |
| Frequency Control Range |
0.1Hz~400Hz |
|
| Frequency Accuracy varied with temperature) |
Digital Command:±0.01%(-10 ~ +40℃),
Analog Command:±0.1% (25℃ ±10℃) |
|
| Frequency Command Resolution |
Digital Command:0.01Hz,
Analog Command:0.06Hz/60Hz |
|
| Frequency Output Resolution |
0.01Hz |
|
| Overload Resistibility |
150% Rated Current for 1 Minute(CT) ; 120%Rated Current for 1Minute(VT) |
|
|
| Frequency Setting Signal |
DC 0 ~ +10V / 4 ~ 20mA |
|
| Acc./Dec. Time |
0.0~6000.0 sec (Accel/Decel Time Can be Set Independent) |
| Voltage-Frequency Characteristics |
V/F Curve Can be Set Through Paramenter Setting(16Types) |
|
| Regeneration Torque |
100%,2%ED,5 sec |
|
| Main Control Function |
Auto Torque Boost, Slip Compensation, Restart After Momentary Power Loss, Energy-Saving, PID Control, |
| RS-485 Communication, Simple PLC Function, Sensorless Vector Control |
| Extra Function |
Up/Down Operation, 4 Different Sets of Fault Status Record (Including Latest One), Cumulative Power On |
| & Operation Hour Memory, Energy Savings Function, MODBUS Communication, Multiple-Pulse Output Ports, etc. |
| Protection Function |
Stall Prevention |
During Acceleration/Deceleration and Constant Speed Operation |
| Current Level can be Selected During Acceleration and Constant Speed Operation |
| During Deceleration, Stall Prevention can be Enabled or Disabled) |
| Instantaneous Overcurrent (OC) |
Stopped if above 200% Rated Current |
|
| Inverter overloads Protection(OL2) |
Stopped if above 150% Rated Current for 1 Minute |
|
| Motor Overload (OL1) |
Electronic Overload Curve Protection |
|
| Over voltage(OV) |
Motor Coasts to Stop if VDC > 410V (230V) or VDC > 820V (460V) |
|
| Low voltage(UV) |
Motor Coasts to Stop if VDC < 200V (230V) or VDC < 400V (460V) |
|
| Momentary Power Loss Ride-Through time |
Motor Coasts to Stop after Momentary Power Loss Lasting > 15ms |
|
| Overheat (OH) |
Protection by Thermistor |
| Grounding Protection (GF) |
Protection by the DC Current Sensor |
|
| Charge Indication |
Light when the DC Bus Voltage ≧50V |
| |
| Mechanical Construction |
Enclosed, Wall-Mounted Type (NEMA-1) |
| Cooling |
Forced |
| Weight(Kg) |
|
| Environmental Conditions |
Location |
Indoor (No Corrosive Gas and Dust Present) |
| Ambient Temperature |
+14 to 104oF, -10 to +40ºC (Not Frozen) |
|
| Storage Temperature |
-4 to 140oF, -20 to +60ºC |
|
| Humidity |
Below 90%RH (Non-Condensing) |
| Altitude, Vibration |
Below 3300ft (1000m), 5.9m/S (0.6G), (JISC0911 Standard) |
| |
| Communication Function |
RS-485 Built-in (MODBUS ) |
| EMI |
Meet EN50081-2 (1994) With Specified EMI Filter |
| EMC Compatibility |
Meet Pr EN50082-2 |