TDS-F8 FREQUENCY INVERTER/TDS-F8-L0P4 INVERTER/TEK DRIVE AC MOTOR DRIVE

TDS-F8 FREQUENCY INVERTER/TDS-F8-L0P4  INVERTER/TEK DRIVE AC MOTOR DRIVE

Model No.︰TDS-F8-L0P4E

Brand Name︰TEK Drive

Country of Origin︰-

Unit Price︰-

Minimum Order︰1 pc

Inquire Now

Product Description

 
 
 
TEK Drive nverters Including TDS-F8 series, TDS-V8 series are very simple to operate, compact and enhance the performance of the motors for various applications at a much higher yield and the depth of its production experience

200-230V,Single phase
0.5Hp/0.4KW

1HP/0.75KW

2Hp/1.5KW

 

nput Voltage Class

Single Phase 220V Class

Model

TDS-F8-L0P4

Max. Applicable Motor HP 0.5
(CT)* KW 0.4
Weight (kg) 1.2
Power Output Rated Output Capacity(kVA) 1.4
Rated Output Current(A) 3.2
Max. Output Voltage 3 Phase 200V~230V
Max. Output Frequency(Hz) Through parameter setting ( Max. 400Hz)
Power Source Rated Voltage, Frequency Single Phase 200V~230V,50/60Hz
Allowable Voltage Fluctuation -15% ~ +10%
Allowable Frequency Fluctuation ±5%
Control Characteristics Operation Mode LED operator
Control Mode Sine PWM
Frequency Control Range 0.1Hz~400Hz
Frequency Accuracy Digital Command:±0.01%(-10 ~ +40℃),
Analog Command:±1% (25℃ ±10℃)
Frequency Command Resolution Digital Command:0.01Hz,
Analog Command:0.06Hz/60Hz
Frequency Output Resolution 0.01Hz
Overload Resistibility (constant torque)150% Rated Current for 60 sec;
Frequency Setting Signal DC 0 ~ +10V / 4 ~ 20mA
Acc./Dec. Time 0.0~999.9 sec ( Accel/Decel Time Can be Set Individually)
Voltage-Frequency Characteristics  V/f Curve Can be Set Through parameter setting
Basic Control Function Auto Torque Boost, Slip Compensation, Restart After Momentary Power Loss, Energy-Saving, PID Control,Simple PLC Function
Extra Function Up/Down Operation,Cumulative Power On & Operation Hour Memory ,4 Different Sets of Fault Status Record (Including Latest One),RS-485 (MODBUS Protocol),Multiple-Pulse Output Ports,1 AnalOg Output Port.
Protection Function Stall Prevention

Current Level Can Be Selected During Acceleration and Constant Speed

Running.During Deceleration,Stall Pervention Can be Enabled or Disabled

Instantaneous Overcurrent (OC) 200% of Rated Output Current
Inverter overloads Protection(OL2) Stop if above 150% Rated Current for 1 Minute
Motor Overload (OL1) Electronic Overload Curve Protection
Over voltage(OV) Stop if VDC ≥410V
Low voltage(UV) Stop if VDC ≤200V
Momentary Power Loss Ride-Through time ≥15ms,stop otherwise
Overheat (OH) Protection by Thermistor
Charge Indication Lit when the DC Bus Voltage ≧50V
Mechanical Construction Enclosed, Wall-Mounted Type (NEMA-1)
Cooling Self      Forced
Weight(Kg)  1.2
Environmental Conditions Location Indoor (No Corrosive Gas and Dust Present)
Ambient Temperature -10 to +40ºC (Not Frozen)
Storage Temperature -20 to +60ºC
Humidity Below 90%RH (Non-Condensing)
Altitude, Vibration Below 3300ft. (1000m), 5.9m/S�U (0.6G), (JISC0911 Standard)
Communication Function RS-485 Built-in(MODBUS)
EMI Meets EN50081-2 (1994) With Specified EMI Filter
EMC Compatibility Meets Pr EN50082-2

Payment Terms︰ T/T in advance or Wester Union

specifications︰ TDS-F8-L0P4E 0.5HP 0.4KW
TEK DRIVE INVERTER/MOTOR DRIVE

Advantages︰ High quality
Competitive price
Timely delivery

Export Markets︰ worldwide

Payment method︰ T/T in advance or Western Union

Min Order︰ 1 pc

Ship Date︰ with 15 days after the receipt of payment

Standard Met︰ UL,CE